環氧樹脂介電常數測試儀

型 號

更新時(shi)間2023-08-08

廠商性(xing)質生產廠家

報價

產品描述:環氧樹脂介電常數測試儀,介電常數測試儀滿足標準:GBT 1409-2006測量電氣絕緣材料在工頻、音頻、高頻(包括米波波長在內)下電容率和介質損耗因數的推薦方法

產品概述

環氧樹脂介電常數測試儀,介電常數測試儀滿足標(biao)準:GBT 1409-2006測量電氣絕緣材料(liao)在工頻、音(yin)頻、高頻(包括(kuo)米波波長在內)下電容率(lv)和介質損耗(hao)因數(shu)的推薦(jian)方(fang)法(fa)

 

介(jie)(jie)質(zhi)損耗和介(jie)(jie)電常(chang)數是各(ge)種電瓷、裝置瓷、電容器等陶瓷,還有復合材料(liao)等的一項重要的物理性質(zhi),通過(guo)測定介(jie)(jie)質(zhi)損耗角正(zheng)切tanδ及(ji)介(jie)(jie)電常(chang)數(ε),可(ke)進一步了解影響介(jie)(jie)質(zhi)損耗和介(jie)(jie)電常(chang)數的各(ge)種因素,為提(ti)高材料(liao)的性能提(ti)供(gong)依據;

儀(yi)器的基本原理是采用高(gao)頻諧振(zhen)法,并提供了,通用、多(duo)(duo)用途、多(duo)(duo)量程(cheng)的阻抗(kang)測試。

 

環氧樹脂介電常數測試儀,介電常數測試儀以單片(pian)計(ji)算機作為(wei)儀器的控制,測量核心(xin)采用(yong)了(le)頻(pin)率(lv)數字(zi)鎖(suo)定(ding),標準頻(pin)率(lv)測試(shi)點自(zi)動(dong)(dong)(dong)設定(ding),諧(xie)振點自(zi)動(dong)(dong)(dong)搜索(suo),Q值(zhi)量程(cheng)自(zi)動(dong)(dong)(dong)轉換,數值(zhi)顯示等新(xin)技術,改進了(le)調諧(xie)回路,使得(de)調諧(xie)測試(shi)回路的殘余電感(gan)減至zui低,并保留了(le)原Q表(biao)中(zhong)自(zi)動(dong)(dong)(dong)穩幅(fu)等技術,使得(de)新(xin)儀器在(zai)使用(yong)時更為(wei)方(fang)便,測量值(zhi)更為(wei)精(jing)確。

 

儀(yi)器能(neng)在較高(gao)的(de)(de)測試頻率(lv)條件(jian)下,測量高(gao)頻電(dian)(dian)(dian)感或諧振回路的(de)(de)Q值,電(dian)(dian)(dian)感器的(de)(de)電(dian)(dian)(dian)感量和分布電(dian)(dian)(dian)容量,電(dian)(dian)(dian)容器的(de)(de)電(dian)(dian)(dian)容量和損(sun)(sun)耗(hao)(hao)角正切值,電(dian)(dian)(dian)工材料的(de)(de)高(gao)頻介(jie)質損(sun)(sun)耗(hao)(hao),高(gao)頻回路有(you)效并聯(lian)及(ji)串聯(lian)電(dian)(dian)(dian)阻(zu),傳(chuan)輸線的(de)(de)特性阻(zu)抗等。 

技術指標

  1.Q值(zhi)測量

 

   a.Q值測量范(fan)圍:2~1023。

   b.Q值量程(cheng)分檔:30、100、300、1000、自動(dong)換(huan)檔或手動(dong)換(huan)檔。

 c.標稱誤差

項    目

GDAT-A

頻率范圍

10kHz~10MHz;

固有誤差

≤5%±滿度值(zhi)的2%;

工作(zuo)誤差

≤7%±滿度值(zhi)的2%;

頻率范圍(wei)

10MHz~160MHz;

固有誤差

≤6%±滿(man)度值的2%;

工作誤差(cha)

≤8%±滿度值的2%。

 

 

 

電(dian)極分開調節

圓筒(tong)電極(ji)(ji)與平板電極(ji)(ji) 分開測量不能用一(yi)體電極(ji)(ji) 精度較差!

環氧樹脂介電常數測試儀特(te)點:

量(liang)程(cheng)高,精度好!

無需換算

彩色觸(chu)摸屏系(xi)統可設置(zhi) 無需切換

 

 

 

 

 

Epoxy resin dielectric constant tester meet standard: GBT 1409-2006 to measure the electrical insulation in power frequency, audio frequency, high frequency (including m wavelength) the recommended method of the dielectric constant and dielectric loss factor
 
 
 
Dielectric loss and dielectric constant are various electrical porcelain, porcelain, capacitor, such as ceramic, and composite materials such as one of the important physical properties, by measuring dielectric loss Angle tangent tan delta and dielectric constant (epsilon), to further understand the various factors influencing the dielectric loss and dielectric constant, and provide the basis for improve the performance of materials;
 
The basic principle of the instrument is to adopt the high frequency resonance method and provide the general, multi-purpose, multi-range impedance test.
 
Epoxy resin dielectric constant test instrument with single chip computer as control instrument, frequency measuring core with the digital lock, standard frequency test point set automatically, automatic resonance point search, Q value range automatic conversion, numerical display new technology, such as improved tuning loop, the tuning test circuit minimizes the residual inductance, and keep the original Q table automatic painting techniques, makes the new instrument when use more convenient, more accurate measurements.
 
 
 
Instrument can under the condition of high test frequency, measuring the high frequency inductive or Q value of resonance loop, inductance and distributed capacitance of inductance and capacitance of capacitor and loss tangent value, electrical material of dielectric loss at high frequency, high frequency circuit effectively in parallel and series resistance, the characteristic impedance of a transmission line, etc.
 
 
 
 
 
Technical index of epoxy resin dielectric constant tester
 
1. Q value measurement
 
 
 
A. Q range: 2 ~ 1023.
 
B. Q value range: 30, 100, 300, 1000, automatic shift or manual shift.
 
C. Nominal error
 
project
GDAT - A
 
Frequency range
10 KHZ ~ 10 MHZ;
 
Inherent error
2% of 5% plus or minus full value;
 
Operating errors
2% of the value of 7% plus or minus;
 
Frequency range
10 MHZ to 160 MHZ;
 
Inherent error
2% of the value of 6% plus or minus.
 
Operating errors
2 percent of the value of 8% plus or minus.
 
 
 
 
 
 
 
Electrode separation adjustment
 
The measurement of the cylinder electrode and the flat electrode can not be measured with one electrode.
 
 
 
 
 
Characteristics of epoxy resin dielectric constant tester:
 