產品概述
多功能電橋式電容率測試儀特點
測(ce)量(liang)工作量(liang)小、快捷簡便(bian)、性能(neng)(neng)穩定、測(ce)量(liang)準確、故障檢出率高;還能(neng)(neng)測(ce)量(liang)電(dian)(dian)(dian)抗(kang)器的(de)電(dian)(dian)(dian)感,放電(dian)(dian)(dian)電(dian)(dian)(dian)阻測(ce)量(liang)功能(neng)(neng),帶電(dian)(dian)(dian)測(ce)量(liang)耦合(he)電(dian)(dian)(dian)容(rong)(rong)器的(de)電(dian)(dian)(dian)流及電(dian)(dian)(dian)容(rong)(rong)量(liang),計算被測(ce)電(dian)(dian)(dian)容(rong)(rong)量(liang)的(de)容(rong)(rong)量(liang);同步(bu)顯(xian)示(shi)電(dian)(dian)(dian)壓及電(dian)(dian)(dian)流波(bo)形(xing)和相位;量(liang)程自(zi)動轉換,存(cun)儲數據(ju);大屏(ping)幕液晶(jing)顯(xian)示(shi),中(zhong)文輸出,并帶打印(yin)。
由于(yu)采(cai)(cai)用標準電容(rong)器、被試電容(rong)器同步采(cai)(cai)樣(yang)技術,可不(bu)受電源(yuan)電壓波動的(de)影(ying)響;加之測量過程是全自動進行的(de),避免了(le)手動操作引起的(de)誤差,因(yin)此具有(you)穩定(ding)性好、重復性好,準確可靠的(de)特(te)點。
使用方法:
1.在試品停電(dian)、*放(fang)電(dian)的條件(jian)下(xia)使(shi)用(yong);
2.本儀器(qi)輸出交流電(dian)壓(ya)20V/2V,功率500W,請確(que)認標(biao)準電(dian)容/電(dian)感(gan)的(de)負(fu)載(zai)能力(li)、額(e)定(ding)電(dian)流。否則(ze)將損壞標(biao)準電(dian)容/電(dian)感(gan)或者(zhe)檢定(ding)結果不準,儀器(qi)檢定(ding)時應良(liang)好接地;
3.將鉗形表(biao)旋(xuan)轉(zhuan)開關設置(zhi)為“OFF",并(bing)將鉗形表(biao)放在測試儀遠端,盡量遠離測試儀;
4.電(dian)流(liu)輸入線一端接(jie)鉗(qian)形(xing)表,一端接(jie)測試(shi)儀,不能懸(xuan)空;
多功能電橋式電容率測試儀注意事項
1、儀器應在技術指標規定的環境中工作,儀器特別是連接測試導線應遠離強電磁場,以免對測量產生干擾。
2、電容電橋測試儀測試完畢或排除故障需打開儀器時,應將電源開關置于關閉位置并拔下電源插頭。
3、儀器測試電纜、電線、夾子應保持清潔,以保證測試接觸良好。
4、儀器開箱后,按照儀器裝箱單,檢查是否相符。
5、在對儀器進行操作前,首先應詳細閱讀該本說明書,或在對本儀器熟悉的人員指導下進行,以免產生誤操作。
6、電源輸入線應與本儀器電源插座相同。
7、由于液晶體受溫度引響,會導致屏幕灰度發生變化,如果字跡不清晰可調節旋鈕。
8、鉗形表一般和電容電橋測試儀一起使用,也可單獨使用,每次用完后請放回保護盒里以免損壞。
- 上(shang)一個: GDAT-A多功能低頻介電常數測定儀
- 下一個(ge): BLD-6000v多功能高壓漏電起痕測試儀